Room Heater Size Calculator: Watts, kW & BTU Needed
Enter your room size, ceiling height, insulation and climate to get the heating power in watts and BTU, the heater size to buy and the running cost.
Insulation covers walls, windows and the floor above or below. Use the price on your energy bill, in your own currency.
Rule-of-thumb estimate for an electric heater. A thermostat cuts power once the room is warm, so real running costs are usually lower. A heat pump uses far less electricity for the same heat.
About this tool
How much heating power does a room need?
Buying a heater that is too small leaves the room cold, and one that is too big wastes money and cycles on and off. This calculator estimates the heating power in watts, kilowatts and BTU per hour from the room size, the ceiling height, how well the room is insulated and how cold your winters are. It then suggests the closest standard heater size and shows what an electric heater would cost to run.
How to use it
- Enter the room area and the ceiling height, in metric or imperial units.
- Pick the insulation level: good (modern, double or triple glazing), average, or poor (old windows, drafts, uninsulated walls).
- Pick the climate that matches your winters.
- Enter your electricity price per kWh and the hours per day you heat the room to see the running cost.
How the calculation works
The room volume is multiplied by a heat demand per cubic metre: 30 W for good insulation, 40 W for average and 55 W for poor insulation. This is the common rule of thumb used by heater retailers. A climate factor then adjusts it: 0.8 for mild, 1.0 for cool, 1.2 for cold and 1.4 for very cold winters. BTU per hour is watts times 3.412. The cost is kilowatts times your price per kWh, assuming the heater runs at full power.
Example
A 20 m² room with a 2.5 m ceiling has 50 m³. With average insulation and cool winters that is 50 x 40 = 2,000 W, about 6,824 BTU/h, so a 2 kW heater fits. At 0.15 per kWh it costs 0.30 per hour at full power, or 72.00 over 30 days at 8 hours a day.
FAQ
Is this exact?
No. It is a rule-of-thumb estimate. Sun exposure, outside walls, floors above unheated rooms and drafts all change the real need.
Why is the real cost lower?
A thermostat switches the heater off once the room is warm, so it rarely runs at full power all day.
Does this work for a heat pump or gas heater?
The power figure is the heat the room needs, so it applies to any heater. The cost, however, is for an electric resistance heater. A heat pump needs about a third of the electricity.